Steam Generator :: Model SFL-2E

Products & Services Photo Gallery About Alladin Air Links Contact Alladin Air

Alladin Air introduces the SFL–2E series. These steam generators incorperate the functional design‚ and all the time honored features of the SFL series such as stainless steel inner canister‚ water pressure safety switch‚ drain‚ and low voltage controls which have made that series the leader in the industry.

But that is just part of the story‚ after thousands of hours of research and development under some of the most severe‚ hard water conditions‚ we have teken that design one step further. With innovations such as dual circuitry for optimun flexability in control‚ our external float mechanism for maximum reliability and serviceability‚ and of course our exclusive dual purpose steam bath/humidification system.

Whatever your application‚ selecting an Alladin Air steam generator is the first step to ensuring your project or renovation is done right.

  1. Self Contained and requires no other fan system
  2. Accurate to the limit of the humidistat
  3. Long Life as a result of stainless steel construction
  4. Minimum maintenance and ease of cleaning
  5. Reliability of few moving parts
  6. Provides water vapor free from mineral salts‚ which remain in stainless steel tank
  7. Capacity is constant since scale is shed from element on cycling‚ dropping to the tank bottom‚ leaving the effective water surface unobstructed

Steam Generator Selection
To select the proper size of steam generator‚ calculate the cubic footage in the following manner:
1. Depth X Width X Height = Cubic Footage. Do not deduct for seating.

2. Adjustments to cubic footage calculation for wall and ceiling material:
    Acrylic or Fiberglass                                   No Adjustment
    Ceramic tile‚ Cultured marble                       +100%
    Glass or Glass block wall                            +30%
    Natural Stone (marble‚ onyx‚ slate‚ etc.)        +100%
    Steam lines over 20ft. (insulate heavily)         +25%
    Cast Iron Tub                                              +25%
    Exterior walls subject to freezing                   +50%

3. Use the unit selection guide below and select your required KW capacity based
    on your previous calculations from step 2.

Unit Selection Guide
Required Capacity KW 1.5 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0
Max. Room Volume Cubic Feet 60 80 100 140 180 220 250 300 350 400

Each steam room is unique. The above information is a recommendation only. Because of variables in construction‚ these sizing instructions should be considered guidelines only. Your distributor or Alladin–Air will review the model selected provided we receive complete information including construction details.

4. Select your appropriate unit from the capacity table by matching the Input
    Capacity & Required Capacity from step 3.

Product Images

Model SFL-2E Steamer Model SFL-2E Steamer Model SFL Steamer
Series SFL Capacity Table
Input KW Model Number Capacity Amps - 1 PH-60 Cy.
  115 Volt 208 Volt 230 Volt lbs/hr kgs/hr 115V 208V 230V
1.5 SFL-IX5MI     4.5 2.1 13.0    
2.0 SFL-2MI SFL-2M8 SFL-2M2 6.0 2.7 17.4 9.6 8.7
3.0   SFL-3M8 SFL-3M2 9.0 4.1   14.4 13.0
4.0   SFL-4M8 SFL-4M2 12.0 5.5   19.2 17.4
5.0   SFL-5M8 SFL-5M2 15.0 6.8   24.0 21.7
Double Circuited Series
6.0   SFL-2E-3M8 SFL-2E-3M2 18.0 8.2   28.8 26.0
7.0   SFL-2E-3/4M8 SFL-2E-3/4M2 21.0 9.6   33.6 30.4
8.0   SFL-2E-4M8 SFL-2E-4M2 24.0 11.0   38.4 34.8
9.0   SFL-2E-4/5M8 SFL-2E-4/5M2 27.0 12.3   43.2 39.1
10.0   SFL-2E-5M8 SFL-2E-5M2 30.0 13.6   48.0 43.4